Function NoMeaningValueMeaning 
  
15Tractor Implement Management Server(Byte 8) 00000100(1) Aux valve 30 state is supportedView
16Tractor Implement Management Client(Byte 8) 00000100(1) Aux valve 30 state is supportedView
15Tractor Implement Management Server(Byte 8) 00001000(1) Aux valve 30 flow is supportedView
16Tractor Implement Management Client(Byte 8) 00001000(1) Aux valve 30 flow is supportedView
15Tractor Implement Management Server(Byte 8) 00010000(1) Aux valve 31 state is supportedView
16Tractor Implement Management Client(Byte 8) 00010000(1) Aux valve 31 state is supportedView
15Tractor Implement Management Server(Byte 8) 00100000(1) Aux valve 31 flow is supportedView
16Tractor Implement Management Client(Byte 8) 00100000(1) Aux valve 31 flow is supportedView
15Tractor Implement Management Server(Byte 8) 01000000(1) Aux valve 32 state is supportedView
16Tractor Implement Management Client(Byte 8) 01000000(1) Aux valve 32 state is supportedView
15Tractor Implement Management Server(Byte 8) 10000000(1) Aux valve 32 flow is supportedView
16Tractor Implement Management Client(Byte 8) 10000000(1) Aux valve 32 flow is supportedView
15Tractor Implement Management Server(Byte 9) bits 1 to 6, values 0 to 32(1) Amount of supported auxiliary valvesView
16Tractor Implement Management Client(Byte 9) bits 1 to 6, values 0 to 32(1) Amount of supported auxiliary valvesView
15Tractor Implement Management Server(Byte 9) bits 7 to 8(1) Reserved for ISO assignmentView
16Tractor Implement Management Client(Byte 9) bits 7 to 8(1) Reserved for ISO assignmentView
0Minimum Control Function00000000(1) No options (Option Number in brackets)View
1Universal Terminal (Server)00000000(1) No optionsView
2Universal Terminal working set (Client)00000000(1) No optionsView
3Aux-O inputs00000000(1) No optionsView
4Aux-O functions00000000(1) No optionsView
7Task Controller Basic Server00000000(1) No optionsView
8Task Controller Basic Client00000000(1) No optionsView
9Task Controller Geo Server00000000(2) No optionsView
13Basic Tractor ECU (Server)00000000(1) TECU not meeting complete class 1 requirementsView
14Basic Tractor ECU implement (Client)00000000(1) TECU not meeting complete class 1 requirementsView
17File Server00000000(1) No optionsView
18File Server Client00000000(1) No optionsView
5Aux-N inputs00000000 00000000 (1) No optionsView
6Aux-N functions00000000 00000000 (1) No optionsView
5Aux-N inputs00000000 00000001 (1) Supports type 0 functionView
6Aux-N functions00000000 00000001 (1) Supports type 0 functionView
5Aux-N inputs00000000 00000010 (1) Supports type 1 functionView
6Aux-N functions00000000 00000010 (1) Supports type 1 functionView
5Aux-N inputs00000000 00000100 (1) Supports type 2 functionView
6Aux-N functions00000000 00000100 (1) Supports type 2 functionView
5Aux-N inputs00000000 00001000 (1) Supports type 3 functionView
6Aux-N functions00000000 00001000 (1) Supports type 3 functionView
5Aux-N inputs00000000 00010000 (1) Supports type 4 functionView
6Aux-N functions00000000 00010000 (1) Supports type 4 functionView
5Aux-N inputs00000000 00100000 (1) Supports type 5 functionView
6Aux-N functions00000000 00100000 (1) Supports type 5 functionView
5Aux-N inputs00000000 01000000 (1) Supports type 6 functionView
6Aux-N functions00000000 01000000 (1) Supports type 6 functionView
5Aux-N inputs00000000 10000000 (1) Supports type 7 functionView
6Aux-N functions00000000 10000000 (1) Supports type 7 functionView
0Minimum Control Function00000001(1) Type I ECU – Internal weak termination View
3Aux-O inputs00000001(1) Supports type 0 functionView
4Aux-O functions00000001(1) Supports type 0 functionView
9Task Controller Geo Server00000001(2) Polygon-based prescription maps are supportedView
13Basic Tractor ECU (Server)00000001(1) Class 1, no optionsView
14Basic Tractor ECU implement (Client)00000001(1) Class 1, no optionsView
5Aux-N inputs00000001 00000000 (1) Supports type 8 functionView
6Aux-N functions00000001 00000000 (1) Supports type 8 functionView
1Universal Terminal (Server)00000001 to 10000000(1) Reserved for ISO assignmentView
2Universal Terminal working set (Client)00000001 to 10000000(1) Reserved for ISO assignmentView
7Task Controller Basic Server00000001 to 10000000(1) Reserved for ISO assignmentView
8Task Controller Basic Client00000001 to 10000000(1) Reserved for ISO assignmentView
17File Server00000001 to 10000000(1) Reserved for ISO assignmentView
18File Server Client00000001 to 10000000(1) Reserved for ISO assignmentView
0Minimum Control Function00000010(1) Type II ECU – Internal end-point terminationView
3Aux-O inputs00000010(1) Supports type 1 functionView
4Aux-O functions00000010(1) Supports type 1 functionView
13Basic Tractor ECU (Server)00000010(1) Class 2, no optionsView
14Basic Tractor ECU implement (Client)00000010(1) Class 2, no optionsView
5Aux-N inputs00000010 00000000 (1) Supports type 9 functionView
6Aux-N functions00000010 00000000 (1) Supports type 9 functionView
9Task Controller Geo Server00000010 to 10000000(2) Reserved for ISO assignmentView
0Minimum Control Function00000100(1) Support of Heartbeat producerView
3Aux-O inputs00000100(1) Supports type 2 functionView
4Aux-O functions00000100(1) Supports type 2 functionView
13Basic Tractor ECU (Server)00000100(1) Lighting option (L)View
14Basic Tractor ECU implement (Client)00000100(1) Class required lighting (L)View
5Aux-N inputs00000100 00000000 (1) Supports type 10 functionView
6Aux-N functions00000100 00000000 (1) Supports type 10 functionView
0Minimum Control Function00001000(1) Support of Heartbeat consumerView
13Basic Tractor ECU (Server)00001000(1) Navigation option (N)View
14Basic Tractor ECU implement (Client)00001000(1) Navigation option (N)View
5Aux-N inputs00001000 00000000 (1) Supports type 11 functionView
6Aux-N functions00001000 00000000 (1) Supports type 11 functionView
3Aux-O inputs00001000 to 10000000(1) Reserved for ISO assignmentView
4Aux-O functions00001000 to 10000000(1) Reserved for ISO assignmentView
13Basic Tractor ECU (Server)00010000(1) Front hitch option (F)View
14Basic Tractor ECU implement (Client)00010000(1) Front hitch option (F)View
5Aux-N inputs00010000 00000000 (1) Supports type 12 functionView
6Aux-N functions00010000 00000000 (1) Supports type 12 functionView
0Minimum Control Function00010000 to 10000000(1) Reserved for ISO assignmentView
13Basic Tractor ECU (Server)00100000(1) Guidance option (G)View
14Basic Tractor ECU implement (Client)00100000(1) Guidance option (G)View
5Aux-N inputs00100000 00000000 (1) Supports type 13 functionView
6Aux-N functions00100000 00000000 (1) Supports type 13 functionView
13Basic Tractor ECU (Server)01000000 (1) Reserved for ISO assignmentView
14Basic Tractor ECU implement (Client)01000000 (1) Reserved for ISO assignmentView
5Aux-N inputs01000000 00000000 (1) Supports type 14 functionView
6Aux-N functions01000000 00000000 (1) Supports type 14 functionView
9Task Controller Geo Server1 to 255(1) Number of control channelsView
10Task Controller Geo Client1 to 255(1) Number of control channelsView
11Task Controller Section Control Server1 to 255(1) Number of supported boomsView
11Task Controller Section Control Server1 to 255(2) Number of supported sectionsView
12Task Controller Section Control Client1 to 255(1) Number of supported boomsView