SPN7443
SP NameStop All Implement Operations Transition Number
SP DescriptionThis parameter indicates the number of transitions from Permit (01) to Stop (00) since power up of the Stop all implement operations parameter. The parameter resets to zero on the next transition after reporting the maximum value.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length8 bits
Scaling256 states/8 bit
Offset0
Data Range0 to 255
Operational RangeNot set
Unitsbit
Slot Identifier93
Slot NameSAEbs08
SP TypeMeasured
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)255
Length minimum (value only)8
Length maximum (value only)8
SP DocumentISO 11783-7
PG Created or Modified Date2014-03-31
PG SP Mapping Created/Mod. Date2014-02-20

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
64770All implements stop operations switch stateView