SPN9732
SP NameAuxiliary valve 0 estimated flow (high resolution)
SP DescriptionValue reported by the controller of flow out of an auxiliary valve 0 of a tractor which could be based on the commanded position of the valve.

0 % indicates no flow, 100 % indicates maximum flow out the extend port, −100 % indicates maximum flow out the retract port. Caution should be exercised when using this parameter in feedback control systems because this parameter is estimated and not measured.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192018
SP Length16 bits
Scaling0.004 %/bit
Offset-125
Data Range-125 to 132.02 %
Operational Range-100 to 100 %
Units%
Slot Identifier264
Slot NameSAEpc09
SP TypeEstimated
SP ReferenceNot set
Scale Factor (value only)0.004
Offset (value only)-125
Range maximum (value only)132.02
Length minimum (value only)16
Length maximum (value only)16
SP DocumentISO 11783-7
PG Created or Modified Date2011-02-03
PG SP Mapping Created/Mod. Date2017-11-20

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65040Auxiliary valve 0 estimated flowView