PGN | 65058 |
---|---|
PG Label | Auxiliary valve 2 measured flow |
PG Acronym | AV02MF |
PG Notes | Message that provides the measurement of auxiliary valve number 02 . |
Pgn Notes | - |
EDP | 0 |
DP | 0 |
PF | 254 |
PS | 34 |
Multipacket | No |
Transmission Rate | 100 ms |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 1.1 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | 2000-08-10 |
PG SP Mapping Created/Mod. Date | 2000-08-10 |
Linked SPNs
Displaying 1-6 of 6 results.
SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
---|---|---|---|---|---|---|
1923 | Auxiliary valve number 02 extend port measured flow | 1 | 8 bits | 1 %/bit | -125 | |
1924 | Auxiliary valve number 02 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1928 | Auxiliary valve number 02 extend port pressure | 3-4 | 16 bits | 5 kPa/bit | 0 | |
1929 | Auxiliary valve number 02 retract port pressure | 5-6 | 16 bits | 5 kPa/bit | 0 | |
1930 | Auxiliary valve number 02 return port pressure | 7 | 8 bits | 16 kPa/bit | 0 | |
5164 | Auxiliary valve number 02 measured flow limit status | 8.6 | 3 bits | 8 states/3 bit | 0 |