SPN2311
SP NameAuxiliary valve number 13 extend port measured flow
SP DescriptionMeasured flow through the extend port of auxiliary valve number 15 of a tractor, expressed as a percentage of full flow.

Zero percent indicates no flow, 100 % indicates maximum flow, −100 % indicates maximum flow returning to the tractor through this port.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length8 bits
Scaling1 %/bit
Offset-125
Data Range-125 to 125 %
Operational RangeNot set
Units%
Slot Identifier45
Slot NameSAEpc05
SP TypeMeasured
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)-125
Range maximum (value only)125
Length minimum (value only)8
Length maximum (value only)8
SP DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65069Auxiliary valve 13 measured flowView