SPN | 5240 |
---|---|
SP Name | Request reset command status |
SP Description | Machine steering system request to the automatic guidance system to change Curvature Command Status state from “Intended to steer” to “Not intended to steer”. Value Meaning 00 Reset not required 01 Reset required 10 Error indication 11 Not available |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2015 |
SP Length | 2 bits |
Scaling | 4 states/2 bit |
Offset | 0 |
Data Range | 0 to 3 |
Operational Range | Not set |
Units | bit |
Slot Identifier | 87 |
Slot Name | SAEbs02 |
SP Type | Measured |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 3 |
Length minimum (value only) | 2 |
Length maximum (value only) | 2 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |