PGN61668
PG LabelHeartbeat Message
PG AcronymHRTBTM
PG NotesThe heartbeat message is used to determine the integrity of the communication of messages and parameters being transmitted by a CF. There may be multiple instances of the heartbeat message on the network. Upon request, each CF shall transmit this message with the appropriate sequence number value.
Pgn NotesImplementation requirements of this message are available in ISO 11783:7.
EDP0
DP0
PF240
PS228
MultipacketNo
Transmission Rate100 ms
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit1.1
PG DocumentISO 11783-7
PG Created or Modified Date2014-02-20
PG SP Mapping Created/Mod. Date2014-02-20

Linked SPNs

Displaying 1-1 of 1 result.
SPNSP NameSP Position In PGSP LengthScalingOffset 
7345Heartbeat sequence number18 bits1 count/bit0View