515 - Track Control State Request changes
DefinitionSpecifies the actual state of Track Control. The value definitions are: Byte 1 Bits 0-1 = 00 manual/off Byte 1 Bits 0-1 = 01 automatic/on Byte 1 Bits 0-1 = 10 error Byte 1 Bits 0-1 = 11 undefined/not supported Byte 1 Bits 2-7 reserved, set to 0. The DDI shall support the OnChange trigger so that the Task Controller is able to get informed when the value gets changed by the Working Set Master. The Task Controller shall activate this trigger when using the DDI.
CommentThe Track Control State has the same purpose and definition like the Section Control State DDI 160. For more details see also attachment on DDI 505.
Typically used by Device Class(es) 4 - Planters /Seeders
Unit Symboln.a. - not applicable
Bit Resolution1
SAE SPN
CANBus Range0 to 3
Display Range0 to 3
Submit Date2015-12-10
Submit ByKarsten Helweg
Submit CompanyCompetence Center ISOBUS e.V.
Revision Number2
Current StatusISO-Published
Status Date2026-01-29
Status CommentsStatus was published
2026-01-29: ISO-Published Status was published
2026-01-26: New Request Submitted
2015-12-10: Request Pending
2016-09-01: ISO-Published

Back