Displaying 1-100 of 305 results.
Function NoMeaningValueMeaning 
  
0Minimum Control Function00000000(1) No options (Option Number in brackets)View
0Minimum Control Function00000001(1) Type I ECU – Internal weak termination View
0Minimum Control Function00000010(1) Type II ECU – Internal end-point terminationView
0Minimum Control Function00000100(1) Support of Heartbeat producerView
0Minimum Control Function00001000(1) Support of Heartbeat consumerView
0Minimum Control Function00010000 to 10000000(1) Reserved for ISO assignmentView
1Universal Terminal (Server)00000000(1) No optionsView
1Universal Terminal (Server)00000001 to 10000000(1) Reserved for ISO assignmentView
2Universal Terminal working set (Client)00000000(1) No optionsView
2Universal Terminal working set (Client)00000001 to 10000000(1) Reserved for ISO assignmentView
3Aux-O inputs00000000(1) No optionsView
3Aux-O inputs00000001(1) Supports type 0 functionView
3Aux-O inputs00000010(1) Supports type 1 functionView
3Aux-O inputs00000100(1) Supports type 2 functionView
3Aux-O inputs00001000 to 10000000(1) Reserved for ISO assignmentView
4Aux-O functions00000000(1) No optionsView
4Aux-O functions00000001(1) Supports type 0 functionView
4Aux-O functions00000010(1) Supports type 1 functionView
4Aux-O functions00000100(1) Supports type 2 functionView
4Aux-O functions00001000 to 10000000(1) Reserved for ISO assignmentView
5Aux-N inputs00000000 00000000 (1) No optionsView
5Aux-N inputs00000000 00000001 (1) Supports type 0 functionView
5Aux-N inputs00000000 00000010 (1) Supports type 1 functionView
5Aux-N inputs00000000 00000100 (1) Supports type 2 functionView
5Aux-N inputs00000000 00001000 (1) Supports type 3 functionView
5Aux-N inputs00000000 00010000 (1) Supports type 4 functionView
5Aux-N inputs00000000 00100000 (1) Supports type 5 functionView
5Aux-N inputs00000000 01000000 (1) Supports type 6 functionView
5Aux-N inputs00000000 10000000 (1) Supports type 7 functionView
5Aux-N inputs00000001 00000000 (1) Supports type 8 functionView
5Aux-N inputs00000010 00000000 (1) Supports type 9 functionView
5Aux-N inputs00000100 00000000 (1) Supports type 10 functionView
5Aux-N inputs00001000 00000000 (1) Supports type 11 functionView
5Aux-N inputs00010000 00000000 (1) Supports type 12 functionView
5Aux-N inputs00100000 00000000 (1) Supports type 13 functionView
5Aux-N inputs01000000 00000000 (1) Supports type 14 functionView
5Aux-N inputs10000000 00000000 (1) Reserved for ISO assignmentView
6Aux-N functions00000000 00000000 (1) No optionsView
6Aux-N functions00000000 00000001 (1) Supports type 0 functionView
6Aux-N functions00000000 00000010 (1) Supports type 1 functionView
6Aux-N functions00000000 00000100 (1) Supports type 2 functionView
6Aux-N functions00000000 00001000 (1) Supports type 3 functionView
6Aux-N functions00000000 00010000 (1) Supports type 4 functionView
6Aux-N functions00000000 00100000 (1) Supports type 5 functionView
6Aux-N functions00000000 01000000 (1) Supports type 6 functionView
6Aux-N functions00000000 10000000 (1) Supports type 7 functionView
6Aux-N functions00000001 00000000 (1) Supports type 8 functionView
6Aux-N functions00000010 00000000 (1) Supports type 9 functionView
6Aux-N functions00000100 00000000 (1) Supports type 10 functionView
6Aux-N functions00001000 00000000 (1) Supports type 11 functionView
6Aux-N functions00010000 00000000 (1) Supports type 12 functionView
6Aux-N functions00100000 00000000 (1) Supports type 13 functionView
6Aux-N functions01000000 00000000 (1) Supports type 14 functionView
6Aux-N functions10000000 00000000 (1) Reserved for ISO assignmentView
7Task Controller Basic Server00000000(1) No optionsView
7Task Controller Basic Server00000001 to 10000000(1) Reserved for ISO assignmentView
8Task Controller Basic Client00000000(1) No optionsView
8Task Controller Basic Client00000001 to 10000000(1) Reserved for ISO assignmentView
9Task Controller Geo Server1 to 255(1) Number of control channelsView
9Task Controller Geo Server00000000(2) No optionsView
9Task Controller Geo Server00000001(2) Polygon-based prescription maps are supportedView
9Task Controller Geo Server00000010 to 10000000(2) Reserved for ISO assignmentView
10Task Controller Geo Client1 to 255(1) Number of control channelsView
11Task Controller Section Control Server1 to 255(1) Number of supported boomsView
11Task Controller Section Control Server1 to 255(2) Number of supported sectionsView
12Task Controller Section Control Client1 to 255(1) Number of supported boomsView
12Task Controller Section Control Client1 to 255(2) Number of supported sectionsView
13Basic Tractor ECU (Server)00000000(1) TECU not meeting complete class 1 requirementsView
13Basic Tractor ECU (Server)00000001(1) Class 1, no optionsView
13Basic Tractor ECU (Server)00000010(1) Class 2, no optionsView
13Basic Tractor ECU (Server)00000100(1) Lighting option (L)View
13Basic Tractor ECU (Server)00001000(1) Navigation option (N)View
13Basic Tractor ECU (Server)00010000(1) Front hitch option (F)View
13Basic Tractor ECU (Server)00100000(1) Guidance option (G)View
13Basic Tractor ECU (Server)01000000 (1) Reserved for ISO assignmentView
13Basic Tractor ECU (Server)10000000(1) Reserved for ISO assignmentView
14Basic Tractor ECU implement (Client)00000000(1) TECU not meeting complete class 1 requirementsView
14Basic Tractor ECU implement (Client)00000001(1) Class 1, no optionsView
14Basic Tractor ECU implement (Client)00000010(1) Class 2, no optionsView
14Basic Tractor ECU implement (Client)00000100(1) Class required lighting (L)View
14Basic Tractor ECU implement (Client)00001000(1) Navigation option (N)View
14Basic Tractor ECU implement (Client)00010000(1) Front hitch option (F)View
14Basic Tractor ECU implement (Client)00100000(1) Guidance option (G)View
14Basic Tractor ECU implement (Client)01000000 (1) Reserved for ISO assignmentView
14Basic Tractor ECU implement (Client)10000000(1) Reserved for ISO assignmentView
15Tractor Implement Management Server(Byte 1) 00000000(1) No options for this option byte supportedView
15Tractor Implement Management Server(Byte 1) 00000001(1) Aux valve 1 state is supportedView
15Tractor Implement Management Server(Byte 1) 00000010(1) Aux valve 1 flow is supportedView
15Tractor Implement Management Server(Byte 1) 00000100(1) Aux valve 2 state is supportedView
15Tractor Implement Management Server(Byte 1) 00001000(1) Aux valve 2 flow is supportedView
15Tractor Implement Management Server(Byte 1) 00010000(1) Aux valve 3 state is supportedView
15Tractor Implement Management Server(Byte 1) 00100000(1) Aux valve 3 flow is supportedView
15Tractor Implement Management Server(Byte 1) 01000000(1) Aux valve 4 state is supportedView
15Tractor Implement Management Server(Byte 1) 10000000(1) Aux valve 4 flow is supportedView
15Tractor Implement Management Server(Byte 2) 00000000(1) No options for this option byte supportedView
15Tractor Implement Management Server(Byte 2) 00000001(1) Aux valve 5 state is supportedView
15Tractor Implement Management Server(Byte 2) 00000010(1) Aux valve 5 flow is supportedView
15Tractor Implement Management Server(Byte 2) 00000100(1) Aux valve 6 state is supportedView
15Tractor Implement Management Server(Byte 2) 00001000(1) Aux valve 6 flow is supportedView
15Tractor Implement Management Server(Byte 2) 00010000(1) Aux valve 7 state is supportedView