Function No | Meaning | Value | Meaning | |
---|---|---|---|---|
0 | Minimum Control Function | 00000000 | (1) No options (Option Number in brackets) | ![]() |
0 | Minimum Control Function | 00000001 | (1) Type I ECU – Internal weak termination | ![]() |
0 | Minimum Control Function | 00000010 | (1) Type II ECU – Internal end-point termination | ![]() |
0 | Minimum Control Function | 00000100 | (1) Support of Heartbeat producer | ![]() |
0 | Minimum Control Function | 00001000 | (1) Support of Heartbeat consumer | ![]() |
0 | Minimum Control Function | 00010000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
1 | Universal Terminal (UT) Server | 00000000 | (1) No options | ![]() |
1 | Universal Terminal (UT) Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
2 | Universal Terminal (UT) Client | 00000000 | (1) No options | ![]() |
2 | Universal Terminal (UT) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
3 | Aux-O inputs | 00000000 | (1) No options | ![]() |
3 | Aux-O inputs | 00000001 | (1) Supports type 0 function | ![]() |
3 | Aux-O inputs | 00000010 | (1) Supports type 1 function | ![]() |
3 | Aux-O inputs | 00000100 | (1) Supports type 2 function | ![]() |
3 | Aux-O inputs | 00001000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
4 | Aux-O functions | 00000000 | (1) No options | ![]() |
4 | Aux-O functions | 00000001 | (1) Supports type 0 function | ![]() |
4 | Aux-O functions | 00000010 | (1) Supports type 1 function | ![]() |
4 | Aux-O functions | 00000100 | (1) Supports type 2 function | ![]() |
4 | Aux-O functions | 00001000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
5 | Aux-N inputs | 00000000 00000000 | (1) No options | ![]() |
5 | Aux-N inputs | 00000000 00000001 | (1) Supports type 0 function | ![]() |
5 | Aux-N inputs | 00000000 00000010 | (1) Supports type 1 function | ![]() |
5 | Aux-N inputs | 00000000 00000100 | (1) Supports type 2 function | ![]() |
5 | Aux-N inputs | 00000000 00001000 | (1) Supports type 3 function | ![]() |
5 | Aux-N inputs | 00000000 00010000 | (1) Supports type 4 function | ![]() |
5 | Aux-N inputs | 00000000 00100000 | (1) Supports type 5 function | ![]() |
5 | Aux-N inputs | 00000000 01000000 | (1) Supports type 6 function | ![]() |
5 | Aux-N inputs | 00000000 10000000 | (1) Supports type 7 function | ![]() |
5 | Aux-N inputs | 00000001 00000000 | (1) Supports type 8 function | ![]() |
5 | Aux-N inputs | 00000010 00000000 | (1) Supports type 9 function | ![]() |
5 | Aux-N inputs | 00000100 00000000 | (1) Supports type 10 function | ![]() |
5 | Aux-N inputs | 00001000 00000000 | (1) Supports type 11 function | ![]() |
5 | Aux-N inputs | 00010000 00000000 | (1) Supports type 12 function | ![]() |
5 | Aux-N inputs | 00100000 00000000 | (1) Supports type 13 function | ![]() |
5 | Aux-N inputs | 01000000 00000000 | (1) Supports type 14 function | ![]() |
5 | Aux-N inputs | 10000000 00000000 | (1) Reserved for ISO assignment | ![]() |
6 | Aux-N functions | 00000000 00000000 | (1) No options | ![]() |
6 | Aux-N functions | 00000000 00000001 | (1) Supports type 0 function | ![]() |
6 | Aux-N functions | 00000000 00000010 | (1) Supports type 1 function | ![]() |
6 | Aux-N functions | 00000000 00000100 | (1) Supports type 2 function | ![]() |
6 | Aux-N functions | 00000000 00001000 | (1) Supports type 3 function | ![]() |
6 | Aux-N functions | 00000000 00010000 | (1) Supports type 4 function | ![]() |
6 | Aux-N functions | 00000000 00100000 | (1) Supports type 5 function | ![]() |
6 | Aux-N functions | 00000000 01000000 | (1) Supports type 6 function | ![]() |
6 | Aux-N functions | 00000000 10000000 | (1) Supports type 7 function | ![]() |
6 | Aux-N functions | 00000001 00000000 | (1) Supports type 8 function | ![]() |
6 | Aux-N functions | 00000010 00000000 | (1) Supports type 9 function | ![]() |
6 | Aux-N functions | 00000100 00000000 | (1) Supports type 10 function | ![]() |
6 | Aux-N functions | 00001000 00000000 | (1) Supports type 11 function | ![]() |
6 | Aux-N functions | 00010000 00000000 | (1) Supports type 12 function | ![]() |
6 | Aux-N functions | 00100000 00000000 | (1) Supports type 13 function | ![]() |
6 | Aux-N functions | 01000000 00000000 | (1) Supports type 14 function | ![]() |
6 | Aux-N functions | 10000000 00000000 | (1) Reserved for ISO assignment | ![]() |
7 | Task Controller Basic (TC Bas) Server | 00000000 | (1) No options | ![]() |
7 | Task Controller Basic (TC Bas) Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
8 | Task Controller Basic (TC Bas) Client | 00000000 | (1) No options | ![]() |
8 | Task Controller Basic (TC Bas) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
9 | Task Controller Geo (TC Geo) Server | 0 to 255 | (1) Number of control channels | ![]() |
9 | Task Controller Geo (TC Geo) Server | 00000000 | (2) No options | ![]() |
9 | Task Controller Geo (TC Geo) Server | 00000001 | (2) Polygon-based prescription maps are supported | ![]() |
9 | Task Controller Geo (TC Geo) Server | 00000010 to 10000000 | (2) Reserved for ISO assignment | ![]() |
10 | Task Controller Geo (TC Geo) Client | 0 to 255 | (1) Number of control channels | ![]() |
11 | Task Controller Section Control (TC SC) Server | 1 to 255 | (1) Number of supported booms | ![]() |
11 | Task Controller Section Control (TC SC) Server | 1 to 255 | (2) Number of supported sections | ![]() |
12 | Task Controller Section Control (TC SC) Client | 1 to 255 | (1) Number of supported booms | ![]() |
12 | Task Controller Section Control (TC SC) Client | 1 to 255 | (2) Number of supported sections | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00000000 | (1) TECU not meeting complete class 1 requirements | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00000001 | (1) Class 1, no options | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00000010 | (1) Class 2, no options | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00000100 | (1) Lighting option (L) | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00001000 | (1) Navigation option (N) | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00010000 | (1) Front hitch option (F) | ![]() |
13 | Basic Tractor ECU (TECU) Server | 00100000 | (1) Guidance option (G) | ![]() |
13 | Basic Tractor ECU (TECU) Server | 01000000 | (1) Reserved for ISO assignment | ![]() |
13 | Basic Tractor ECU (TECU) Server | 10000000 | (1) Reserved for ISO assignment | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00000000 | (1) TECU not meeting complete class 1 requirements | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00000001 | (1) Class 1, no options | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00000010 | (1) Class 2, no options | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00000100 | (1) Class required lighting (L) | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00001000 | (1) Navigation option (N) | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00010000 | (1) Front hitch option (F) | ![]() |
14 | Basic Tractor ECU (TECU) Client | 00100000 | (1) Guidance option (G) | ![]() |
14 | Basic Tractor ECU (TECU) Client | 01000000 | (1) Reserved for ISO assignment | ![]() |
14 | Basic Tractor ECU (TECU) Client | 10000000 | (1) Reserved for ISO assignment | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00000000 | (1) No options for this option byte supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00000001 | (1) Aux valve 1 state is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00000010 | (1) Aux valve 1 flow is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00000100 | (1) Aux valve 2 state is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00001000 | (1) Aux valve 2 flow is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00010000 | (1) Aux valve 3 state is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 00100000 | (1) Aux valve 3 flow is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 01000000 | (1) Aux valve 4 state is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 1) 10000000 | (1) Aux valve 4 flow is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 2) 00000000 | (1) No options for this option byte supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 2) 00000001 | (1) Aux valve 5 state is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 2) 00000010 | (1) Aux valve 5 flow is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 2) 00000100 | (1) Aux valve 6 state is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 2) 00001000 | (1) Aux valve 6 flow is supported | ![]() |
15 | Tractor Implement Management (TIM) Server | (Byte 2) 00010000 | (1) Aux valve 7 state is supported | ![]() |