Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 101-200 of 330 results.
| Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0100 0000 | Aux valve 8 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0001 | Aux valve 9 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0100 | Aux valve 10 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 1000 | Aux valve 10 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0001 0000 | Aux valve 11 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0010 0000 | Aux valve 11 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0100 0000 | Aux valve 12 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 1000 0000 | Aux valve 12 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0000 0001 | Aux valve 13 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0000 0010 | Aux valve 13 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0000 0100 | Aux valve 14 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0000 1000 | Aux valve 14 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0001 0000 | Aux valve 15 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0010 0000 | Aux valve 15 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 0100 0000 | Aux valve 16 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 4) 1000 0000 | Aux valve 16 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0000 0001 | Aux valve 17 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0000 0010 | Aux valve 17 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0000 0100 | Aux valve 18 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0000 1000 | Aux valve 18 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0001 0000 | Aux valve 19 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0010 0000 | Aux valve 19 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 0100 0000 | Aux valve 20 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 5) 1000 0000 | Aux valve 20 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0000 0001 | Aux valve 21 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0000 0010 | Aux valve 21 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0000 0100 | Aux valve 22 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0000 1000 | Aux valve 22 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0001 0000 | Aux valve 23 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0010 0000 | Aux valve 23 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 0100 0000 | Aux valve 24 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 6) 1000 0000 | Aux valve 24 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 0001 | Aux valve 25 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 0010 | Aux valve 25 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 0100 | Aux valve 26 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 1000 | Aux valve 26 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0001 0000 | Aux valve 27 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0010 0000 | Aux valve 27 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0100 0000 | Aux valve 28 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 7) 1000 0000 | Aux valve 28 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0001 | Aux valve 29 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0010 | Aux valve 29 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0100 | Aux valve 30 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 1000 | Aux valve 30 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0001 0000 | Aux valve 31 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0010 0000 | Aux valve 31 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0100 0000 | Aux valve 32 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 8) 1000 0000 | Aux valve 32 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 9) bits 1 to 6, values 0 to 32 | Amount of supported auxiliary valves | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 9) bits 7 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0001 | Front PTO disengagement is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0010 | Front PTO engagement CCW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0100 | Front PTO engagement CW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 1000 | Front PTO speed CCW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0001 0000 | Front PTO speed CW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 10) bits 6 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0001 | Rear PTO disengagement is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0010 | Rear PTO engagement CCW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0100 | Rear PTO engagement CW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 1000 | Rear PTO speed CCW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0001 | Front hitch motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0010 | Front hitch position is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0001 | Rear hitch motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0010 | Rear hitch position is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 1000 0000 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0001 | Guidance curvature is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0000 0001 | Aux valve 1 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0000 0010 | Aux valve 1 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0000 0100 | Aux valve 2 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0000 1000 | Aux valve 2 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0001 0000 | Aux valve 3 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0010 0000 | Aux valve 3 flow is supported | ![]() |