Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 330 results.
Function NoMeaningValueMeaning 
  
9Task Controller Geo (TC-GEO) Server(Byte 1) 0 to 255Number of control channelsView
10Task Controller Geo (TC-GEO) Client(Byte 1) 0 to 255Number of control channelsView
0Minimum Control Function(Byte 1) 0000 0000No optionsView
1Universal Terminal (UT) Server(Byte 1) 0000 0000No optionsView
2Universal Terminal (UT) Client(Byte 1) 0000 0000No optionsView
3Aux-O inputs(Byte 1) 0000 0000No optionsView
4Aux-O functions(Byte 1) 0000 0000No optionsView
5Aux-N inputs(Byte 1) 0000 0000No options for this option byte supportedView
6Aux-N functions(Byte 1) 0000 0000No options for this option byte supportedView
17File Server(Byte 1) 0000 0000No optionsView
18File Server Client(Byte 1) 0000 0000No optionsView
19Sequence Controller (SQC) Server(Byte 1) 0000 0000No optionsView
20Sequence Controller (SQC) Client(Byte 1) 0000 0000No optionsView
21ISOBUS Shortcut Button (ISB) Server(Byte 1) 0000 0000No optionsView
22ISOBUS Shortcut Button (ISB) Client(Byte 1) 0000 0000No optionsView
7Task Controller Basic (TC-BAS) Server(Byte 1) 0000 0000No optionsView
24Datalogger (LOG) Server(Byte 1) 0000 0000No options for this option byte supportedView
8Task Controller Basic (TC-BAS) Client(Byte 1) 0000 0000No optionsView
25Datalogger (LOG) Client(Byte 1) 0000 0000No optionsView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0000No options for this option byte supportedView
27Task Controller Tramline (TRACK) Server(Byte 1) 0000 0000No options for this option byte supportedView
13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0000No options for this option byte supportedView
14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsView
15Tractor Implement Management (TIM) Server(Byte 1) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0000No options for this option byte supportedView
0Minimum Control Function(Byte 1) 0000 0001Type I ECU – Internal weak termination View
3Aux-O inputs(Byte 1) 0000 0001Supports type 0 functionView
4Aux-O functions(Byte 1) 0000 0001Supports type 0 functionView
5Aux-N inputs(Byte 1) 0000 0001Supports type 0 functionView
6Aux-N functions(Byte 1) 0000 0001Supports type 0 functionView
24Datalogger (LOG) Server(Byte 1) 0000 0001Data logger (LOG) service type supports FMIS interfaceView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationView
13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0001Class 1, no optionsView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionView
14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0001Class 1, no optionsView
15Tractor Implement Management (TIM) Server(Byte 1) 0000 0001Aux valve 1 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0001Aux valve 1 state is supportedView
0Minimum Control Function(Byte 1) 0000 0010Type II ECU – Internal end-point terminationView
3Aux-O inputs(Byte 1) 0000 0010Supports type 1 functionView
4Aux-O functions(Byte 1) 0000 0010Supports type 1 functionView
5Aux-N inputs(Byte 1) 0000 0010Supports type 1 functionView
6Aux-N functions(Byte 1) 0000 0010Supports type 1 functionView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportView
13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0010Class 2, no optionsView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersView
14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0010Class 2, no optionsView
15Tractor Implement Management (TIM) Server(Byte 1) 0000 0010Aux valve 1 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0010Aux valve 1 flow is supportedView
0Minimum Control Function(Byte 1) 0000 0100Support of Heartbeat producerView
3Aux-O inputs(Byte 1) 0000 0100Supports type 2 functionView
4Aux-O functions(Byte 1) 0000 0100Supports type 2 functionView
5Aux-N inputs(Byte 1) 0000 0100Supports type 2 functionView
6Aux-N functions(Byte 1) 0000 0100Supports type 2 functionView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityView
13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0100Lighting option (L)View
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlView
14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0100Class required lighting (L)View
15Tractor Implement Management (TIM) Server(Byte 1) 0000 0100Aux valve 2 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0100Aux valve 2 state is supportedView
0Minimum Control Function(Byte 1) 0000 1000Support of Heartbeat consumerView
5Aux-N inputs(Byte 1) 0000 1000Supports type 3 functionView
6Aux-N functions(Byte 1) 0000 1000Supports type 3 functionView
13Basic Tractor ECU (TECU) Server(Byte 1) 0000 1000Navigation option (N)View
14Basic Tractor ECU (TECU) Client(Byte 1) 0000 1000Navigation option (N)View
15Tractor Implement Management (TIM) Server(Byte 1) 0000 1000Aux valve 2 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 1000Aux valve 2 flow is supportedView
5Aux-N inputs(Byte 1) 0001 0000Supports type 4 functionView
6Aux-N functions(Byte 1) 0001 0000Supports type 4 functionView
13Basic Tractor ECU (TECU) Server(Byte 1) 0001 0000Front hitch option (F)View
14Basic Tractor ECU (TECU) Client(Byte 1) 0001 0000Front hitch option (F)View
15Tractor Implement Management (TIM) Server(Byte 1) 0001 0000Aux valve 3 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0001 0000Aux valve 3 state is supportedView
5Aux-N inputs(Byte 1) 0010 0000Supports type 5 functionView
6Aux-N functions(Byte 1) 0010 0000Supports type 5 functionView
13Basic Tractor ECU (TECU) Server(Byte 1) 0010 0000Guidance option (G)View
14Basic Tractor ECU (TECU) Client(Byte 1) 0010 0000Guidance option (G)View
15Tractor Implement Management (TIM) Server(Byte 1) 0010 0000Aux valve 3 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0010 0000Aux valve 3 flow is supportedView
5Aux-N inputs(Byte 1) 0100 0000Supports type 6 functionView
6Aux-N functions(Byte 1) 0100 0000Supports type 6 functionView
15Tractor Implement Management (TIM) Server(Byte 1) 0100 0000Aux valve 4 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0100 0000Aux valve 4 state is supportedView
11Task Controller Section Control (TC-SC) Server(Byte 1) 1 to 255Number of supported boomsView
12Task Controller Section Control (TC-SC) Client(Byte 1) 1 to 255Number of supported boomsView
5Aux-N inputs(Byte 1) 1000 0000Supports type 7 functionView
6Aux-N functions(Byte 1) 1000 0000Supports type 7 functionView
15Tractor Implement Management (TIM) Server(Byte 1) 1000 0000Aux valve 4 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 1000 0000Aux valve 4 flow is supportedView
1Universal Terminal (UT) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
2Universal Terminal (UT) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
7Task Controller Basic (TC-BAS) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
8Task Controller Basic (TC-BAS) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView