Details for DDEntity "516 - Tramline Overdosing Rate"
| 516 - Tramline Overdosing Rate Request changes |
|---|
| Definition | This DDI specifies the tramline overdosing rate for the rows adjacent to the tramline tire path. |
|---|---|
| Comment | This DDI is an implement track parameter and specifies the tramline overdosing rate for the rows adjacent to the tramline tire path. The value is specified in ppm. The value 1.000.000 (100 %) is the normal rate. A value > 100 % means that a overdosing is applied. For more details see also attachment on DDI 505. |
| Typically used by Device Class(es) |
4 -
Planters /Seeders |
|---|
| Unit Symbol | ppm - |
|---|---|
| Bit Resolution | 1 |
| SAE SPN | |
| CANBus Range | 0 to 2147483647 |
| Display Range | 0 to 2147483647 |
| Submit Date | 2015-12-10 |
| Submit By | Karsten Helweg |
| Submit Company | Competence Center ISOBUS e.V. |
| Revision Number | 2 |
| Current Status | ISO-Published |
| Status Date | 2026-01-29 |
| Status Comments | Status was published |
|
|
|
|
2026-01-29: ISO-Published
Status was published
2026-01-26: New Request Submitted
2015-12-10: Request Pending
2016-09-01: ISO-Published
|