Details for DDEntity "141 - Actual Work State"
141 - Actual Work State Request changes |
---|
Definition | Actual Work State, 2 bits defined as 00=disabled/off, 01=enabled/on, 10=error, 11=undefined/not installed |
---|---|
Comment | See the DDI 290 attachment "ISO11783-11-DDI-289-SetpointWorkState" as reference for implementation guideline. This DDE has been revised in 2012 to be used as the Actual Work State. A separate Setpoint Work State was added to the data dictionary at that time. Original comment: this DDE was a result of March 2005 TF10 meeting. |
Typically used by Device Class(es) |
0 -
Non-specific system 1 - Tractor 2 - Primary Soil Tillage 3 - Secondary Soil Tillage 4 - Planters /Seeders 5 - Fertilizer 6 - Sprayers 7 - Harvesters 8 - Root Harvester 9 - Forage harvester 10 - Irrigation 11 - Transport / Trailers 12 - Farmyard Work 13 - Powered Auxilary Units 14 - Special Crops 15 - Municipal Work 17 - Sensor System |
---|
Unit Symbol | n.a. - not applicable |
---|---|
Bit Resolution | 1 |
SAE SPN | not specified |
CANBus Range | 0 to 3 |
Display Range | 0 to 3 |
Submit Date | 2005-03-01 |
Submit By | 11783-Part 10 Task Force |
Submit Company | 89 - Kverneland Group, Electronics Division |
Revision Number | 1 |
Current Status | ISO-Published |
Status Date | 2012-04-02 |
Status Comments |
|
|
2012-04-02: ISO-Published
2012-04-02: ISO-Submitted (Pending)
2005-05-09: ISO-Published
DDEs have been moved to published for creating the new Annex A version.
2005-03-01: ISO-Approved
2005-03-01: ISO-Submitted (Pending)
|