Details for DDEntity "266 - Lifetime Application Total Mass"
266 - Lifetime Application Total Mass Request changes |
---|
Definition | Entire Application Total Mass of the device lifetime. |
---|---|
Comment | This is the overall total of the device. This total does not refer to an application controlled by a Task Controller. Therefore this DDE shall not be setable within the device description and neither shall the device reset the value when the task status changes. It is up to the device control system when to reset this value. The Working Set Master shall support the total trigger method for this DDE but shall not support the setable property. The Task Controller can request and store this DDE at the end of a task. But it shall not set this DDE when the task is resumed. |
Typically used by Device Class(es) |
4 -
Planters /Seeders 5 - Fertilizer 6 - Sprayers |
---|
Unit Symbol | kg - |
---|---|
Bit Resolution | 1 |
SAE SPN | |
CANBus Range | 0 to 2147483647 |
Display Range | 0 to 2147483647 |
Submit Date | 2012-01-09 |
Submit By | Matthias Meyer |
Submit Company | John Deere |
Revision Number | 1 |
Current Status | ISO-Approved |
Status Date | 2012-02-15 |
Status Comments | Status was approved |
|
|
2012-02-15: ISO-Approved
Status was approved
2012-02-15: ISO-Published
2012-01-09: Request Pending
|