Details for DDEntity "288 - Actual Prescription Mode"
288 - Actual Prescription Mode Request changes |
---|
Definition | This DDE defines the actual source of the set point value used by the Control Function. This DDI shall be defined as DPD in the DDOP and shall not be setable and need to support the on change trigger. The TC should request this DDI in case of an active prescription operation for documentation purpose. |
---|---|
Comment | The Control Function Prescription Mode sahll have one of the following values: 0 = Unknown / not defined 1 = TC rate 2 = Manual Entry 3 = Peer Control 4 = Max override 5 = Min override 6 and higher are reserved for future assignments |
Typically used by Device Class(es) |
4 -
Planters /Seeders 5 - Fertilizer 6 - Sprayers |
---|
Unit Symbol | n.a. - not applicable |
---|---|
Bit Resolution | 1 |
SAE SPN | |
CANBus Range | 0 to 5 |
Display Range | 0 to 5 |
Submit Date | 2013-09-23 |
Submit By | Joe Tevis |
Submit Company | Topcon |
Revision Number | 2 |
Current Status | Published |
Status Date | 2022-10-28 |
Status Comments | Change status to published |
|
|
2022-10-28: Published
Change status to published
2015-07-30: ISO-Submitted (Pending)
2013-09-23: Request Pending
|