Details for DDEntity "365 - Setpoint Downforce Pressure"

365 - Setpoint Downforce Pressure Request changes
DefinitionSetpoint downforce pressure for an operation
CommentThis value represents the system pressure to produce the downforce (or upforce) for an operation messured in Pa (Pascal); In case of an negative value the system pressure would produce Upforce.
Typically used by Device Class(es) 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
Unit SymbolPa -
Bit Resolution1
SAE SPN
CANBus Range-2147483648 to 2147483647
Display Range-2147483648 to 2147483647
Submit Date2014-12-04
Submit ByBrandon McDonald
Submit CompanyJohn Deere
Revision Number1
Current StatusISO-Published
Status Date2015-01-13
Status Comments
2015-01-13: ISO-Published
2014-12-04: Request Pending

Back