Details for DDEntity "389 - Setpoint Revolutions specified as count per time"

389 - Setpoint Revolutions specified as count per time Request changes
DefinitionSetpoint Revolutions specified as count per time
CommentForward or Clockwise rotation represented as positive numbers and reverse or Counter-Clockwise rotation represented by negative numbers. To prevent rounding errors the basic unit r/min where chosen.
Typically used by Device Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbolr/min -
Bit Resolution0,0001
SAE SPN
CANBus Range-2147483648 to 2147483647
Display Range-214748,3648 to 214748,3647
Submit Date2015-04-24
Submit ByDavid Kuhnel
Submit CompanyDICKEY-john Corp
Revision Number1
Current StatusISO-Published
Status Date2015-04-24
Status Comments
2015-04-24: ISO-Published