Details for DDEntity "465 - Lifetime Haul Counter"

465 - Lifetime Haul Counter Request changes
DefinitionThe number of haul cycles done by a machine over its entire lifetime. This DDE value can not be set through the process data interface but can be requested and added to a datalog. This DDE value is not affected by a task based total haul cycles but will increment at the same rate as the task based total.
CommentThis is the overall total of the device. This total does not refer to an application controlled by a Task Controller. Therefore this DDE shall not be setable within the device description and neither shall the device reset the value when the task status changes. It is up to the device control system when to reset this value. The Working Set Master shall support the total trigger method for this DDE but shall not support the setable property. The Task Controller can request and store this DDE at the end of a task. But it shall not set this DDE when the task is resumed.
Typically used by Device Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
17 - Sensor System
Unit Symbol# -
Bit Resolution1
SAE SPN
CANBus Range0 to 2147483647
Display Range0 to 2147483647
Submit Date2015-07-24
Submit ByFranz Hoepfinger
Submit Company367 - Fliegl Agrartechnik GmbH
Revision Number2
Current StatusISO-Published
Status Date2015-12-14
Status Comments
2015-12-14: ISO-Published
2015-07-24: Request Pending This DDE was a result of Jul 2015 AEF PT9 FMIS SG Transport meeting.

Back