Details for DDEntity "379 - Condensed Section Override State (193-208) "

379 - Condensed Section Override State (193-208) Request changes
DefinitionThis DDE is used by the implement to communicate that a certain section is overridden and will not follow the section control commands. The value is a combination of the override states of individual sections number 193 to 208 into a single override state. The condensed section override state contains the child element override states, in the driving direction from left to right, where the leftmost child element override state are the 2 lowest significant bits of the Process Data Value. Each child device elements override state is represented by 2 bits and defined as: 00 = section is not overridden, 01 = section is overridden, 10 = reserved, 11 = undefined / not installed. In total 16 child device element override states can be contained in one condensed section override state. If less than 16 child device element override states are available, then the unused bits shall be set to value 11 (undefined / not installed). This DDE shall be placed in the same device element as the corresponding actual condensed work state.
CommentIt is common for SC servers to show the current state of the sections in a proprietary screen. As the implement is allowed to override the commanded state from the task controller it is impossible for the operator to predict what happens when driving into an unworked area. With this DDE it is possible for the SC server to show overridden sections in the proprietary screen. This DDE shall be defined as DPD in the DDOP of the implement. The DPD shall at least support the datalog triggers “on change” and “time based”. The value shall only be sent by the implement if it was requested (single request or datalog trigger) by the TC-SC server.
Typically used by Device Class(es) 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
Unit Symbolnot defined -
Bit Resolution1
SAE SPN
CANBus Range0 to 4294967295
Display Range0 to 4294967295
Submit Date2015-01-21
Submit ByMichael Köcher
Submit Company AMAZONEN-Werke H. Dreyer GmbH & Co. KG
Revision Number2
Current StatusISO-Published
Status Date2016-06-27
Status CommentsStatus was published
2016-06-27: ISO-Published Status was published
2016-06-27: Request Pending Replace character "–" in the DDI Name by ASCII Character for better processability of the txt export
2015-01-21: ISO-Published

Back