Details for DDEntity "546 - Lifetime Chopping Engagement Total Time"

546 - Lifetime Chopping Engagement Total Time Request changes
DefinitionEntire Chopping Engagement Total Time of the device lifetime.
CommentThis is the overall total of the device. This total does not refer to an application controlled by a Task Controller. Therefore this DDE shall not be setable within the device description and neither shall the device reset the value when the task status changed. It is up to the device control system when to reset this value. The Working Set Master shall support the total trigger method for this DDE but shall not support the setable property. The Task Controller can request and store this DDE at the end of a task. But it shall not set this DDE when the task is resumed.
Typically used by Device Class(es) - Not Assigned
Unit Symbols - second
Bit Resolution1
SAE SPN
CANBus Range0 to 2147483647
Display Range0 to 2147483647
Submit Date2018-06-25
Submit ByMarc-Kevin Doeker
Submit CompanyMaschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number1
Current StatusPublished
Status Date2018-07-11
Status Comments
2018-07-11: Published
2018-06-25: New Request Submitted

Back