Details for DDEntity "588 - Setpoint Volume Per Area Application Rate as [ml/m²]"

588 - Setpoint Volume Per Area Application Rate as [ml/m²] Request changes
DefinitionSetpoint Application Rate specified as volume per area for High Flows as [mm³/m²]
CommentNew DDI which supports higher flows is being needed. Use case: Manure Application with 28000 gal/acre
Typically used by Device Class(es) 10 - Irrigation
25 - Slurry Applicators
Unit Symbolml/m² -
Bit Resolution0,1
SAE SPN
CANBus Range0 to 2147483647
Display Range0 to 214748364,7
Submit Date2019-04-12
Submit ByStefan Welsch
Submit Company33 - John Deere
Revision Number1
Current StatusISO-Published
Status Date2019-05-02
Status CommentsStatus was published
2019-05-02: ISO-Published Status was published
2019-04-12: New Request Submitted

Back