Details for DDEntity "591 - Maximum Volume Per Area Application Rate as [ml/m²]"
| 591 - Maximum Volume Per Area Application Rate as [ml/m²] Request changes |
|---|
| Definition | Maximum Volume Per Area Application Rate for high flows as [ml/m²] |
|---|---|
| Comment | DDI which supports higher flows is being needed. Use case: Manure Application with 28000 gal/acre |
| Typically used by Device Class(es) |
10 -
Irrigation 25 - Slurry Applicators |
|---|
| Unit Symbol | ml/m² - |
|---|---|
| Bit Resolution | 0,1 |
| SAE SPN | |
| CANBus Range | 0 to 2147483647 |
| Display Range | 0 to 214748364,7 |
| Submit Date | 2019-05-02 |
| Submit By | Stefan Welsch |
| Submit Company | John Deere |
| Revision Number | 1 |
| Current Status | Published |
| Status Date | 2019-05-02 |
| Status Comments |
|
|
|
|
2019-05-02: Published
|