Details for DDEntity "240 - Actual (Un)Loading System Status"

240 - Actual (Un)Loading System Status Request changes
DefinitionActual status of the Unloading and/or Loading system. This DDE covers both Unloading and Loading of the device element wherein it is listed. Bits that are not mentioned are reserved and shall be set to 1. Byte 1: 2 bit unloading status indicator, bit 1 and 2: 00=disabled/off 01=enabled/on/unloading 10=error 11=undefined/not installed Byte 2: 2 bit loading status indicator, bit 1 and 2: 00=disabled/off 01=enabled/on/loading 10=error 11=undefined/not installed Byte 3: set to FF Byte 4: set to FF
CommentNote: The bits of a byte are defined from 1 to 8 (87654321)
Typically used by Device Class(es) 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
Unit Symboln.a. - not applicable
Bit Resolution1
SAE SPN
CANBus Range-2147483648 to 2147483647
Display Range0 to 2147483647
Submit Date2011-07-08
Submit ByRobert Waggoner
Submit CompanyAGCO
Revision Number2
Current StatusNew Request Submitted
Status Date2020-04-23
Status Commentsadded that byte 3 and 4 shall be set to FF; The value that is transferred over the canbus can be negative
2020-04-23: New Request Submitted added that byte 3 and 4 shall be set to FF; The value that is transferred over the canbus can be negative
2019-12-16: ISO-Published Status was published
2019-12-04: New Request Submitted Max value is 0x303 (hex) = 771 (decimal)
2011-10-17: ISO-Published

Back