Details for DDEntity "240 - Actual (Un)Loading System Status"
240 - Actual (Un)Loading System Status Request changes |
---|
Definition | Actual status of the Unloading and/or Loading system. This DDE covers both Unloading and Loading of the device element wherein it is listed. Bits that are not mentioned are reserved and shall be set to 1. Byte 1: 2 bit unloading status indicator, bit 1 and 2: 00=disabled/off 01=enabled/on/unloading 10=error 11=undefined/not installed Byte 2: 2 bit loading status indicator, bit 1 and 2: 00=disabled/off 01=enabled/on/loading 10=error 11=undefined/not installed Byte 3: set to FF Byte 4: set to FF |
---|---|
Comment | Note: The bits of a byte are defined from 1 to 8 (87654321) |
Typically used by Device Class(es) |
7 -
Harvesters 8 - Root Harvester 9 - Forage harvester 14 - Special Crops |
---|
Unit Symbol | n.a. - not applicable |
---|---|
Bit Resolution | 1 |
SAE SPN | |
CANBus Range | -2147483648 to 2147483647 |
Display Range | 0 to 2147483647 |
Submit Date | 2011-07-08 |
Submit By | Robert Waggoner |
Submit Company | AGCO |
Revision Number | 2 |
Current Status | New Request Submitted |
Status Date | 2020-04-23 |
Status Comments | added that byte 3 and 4 shall be set to FF; The value that is transferred over the canbus can be negative |
|
|
2020-04-23: New Request Submitted
added that byte 3 and 4 shall be set to FF; The value that is transferred over the canbus can be negative
2019-12-16: ISO-Published
Status was published
2019-12-04: New Request Submitted
Max value is 0x303 (hex) = 771 (decimal)
2011-10-17: ISO-Published
|