Details for DDEntity "595 - Machine Mode"

595 - Machine Mode Request changes
DefinitionThis mode does represent the overall current machine mode and shall be used only one time within the DDOP below the device element of type device. If a machine is capable of differentiating between different modes it can be indicated by this mode. The value definitions are 0 = Unknown / Not defined 1 = Idle 2 = Field Mode 3 = Street Mode 4 = Maintenance 5 = Filling 6 = Emptying 7 = Cleaning 8 and higher are reserved for future assignments
CommentIn addition to the current workstate, some machines are capable of differentiating between different modes. In idle/neutral mode, value 1 (Idle) should be used. If a machine is in working/field mode, value 2 (Field Mode) should be indicated. Moving the machine on a road/street should be indicated by value 3 (Street Mode). During maintenance/servicing, the value 4 (Maintenance) must be selected. If the machine is in an unspecified state, value 0 (Unknown / Not defined) should be used. Note: this mode does not define the Work State of a machine function Examples: * A sprayer in the field performing a spraying application is in field mode. A sprayer at the farm filling the bin is in filling mode * A combine harvesting in the field would be in field mode. To indicate unloading the harvester bin DDI 240 should be used
Typically used by Device Class(es) - Not Assigned
0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
17 - Sensor System
18 - Reserved for Future Assignment
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
23 - Mulchers
24 - Utility Vehicles
25 - Slurry Applicators
26 - Feeder / Mixer
Unit Symboln.a. - not applicable
Bit Resolution1
SAE SPN
CANBus Range0 to 2147483647
Display Range0 to 2147483647
Submit Date2019-12-04
Submit ByMarc-Kevin Doeker
Submit CompanyMaschinenfabrik Bernard Krone GmbH & Co. KG
Revision Number1
Current StatusPublished
Status Date2020-09-21
Status CommentsAdded mode 5 to 7; Update definition and comment
2020-09-21: Published Added mode 5 to 7; Update definition and comment
2019-12-16: Published
2019-12-16: ISO-Published Status was published
2019-12-04: New Request Submitted

Back