Details for DDEntity "49152 - Setpoint Droplet Size"

49152 - Setpoint Droplet Size Request changes
DefinitionThe setpoint for droplet size. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
CommentDroplet sizes are currently defined in ISO 25358 and are broken into 8 classification categories and also assigned a corresponding colour code as follows: Extremely Fine = Purple, Very Fine = Red, Fine = Orange, Medium = Yellow, Coarse = Green, Very Coarse = Blue, Extremely Coarse = White, Ultra Coarse = Black
Typically used by Device Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Unit Symboln.a. - not applicable
Bit Resolution1
SAE SPN
CANBus Range0 to 255
Display Range0 to 255
Submit Date2021-03-08
Submit ByJohn Summers
Submit CompanyTeeJet Technologies
Revision Number1
Current StatusPublished
Status Date2021-05-12
Status Comments
2021-05-12: Published
2021-05-12: ISO-Published Status was published
2021-03-08: New Request Submitted

Back