Details for DDEntity "206 - SC Setpoint Turn Off Time"

206 - SC Setpoint Turn Off Time Request changes
DefinitionThe Section Control Turn Off Time defines the overall time lapse between the moment the TC sends a turn off section command to the working set and the moment this section is physically turned off. The working set may support this DDE as an optional feature to provide the possibility to store the time settings direct on the device to make the settings available after a power cycle. Therefore this DDE needs always to be setable by the TC and shall not be used to change any working set system behavior. The DDI shall support the On Change trigger so that the TC is able to get informed when the value gets changed by the Working Set Master. The TC shall active this trigger when using the DDI.
CommentThe SC Turn Off Time setting is used to compensate the average physical machine reaction time (Electrical & Mechanical) from the moment the Task Controller send the command and the Working Set turns off the sections. To find the right time setting for the used system combination of Task Controller and Working Set it could take awhile and therefore it is a big benefit to store the setting on the Working Set to make them again available after a power cycle. For Working Sets supporting Section Control it is recommended to add SC Turn Off Time to its device description and make it setable. See also DDI 205 including attachment and DDI 656 and 657
Typically used by Device Class(es) 0 - Non-specific system
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Unit Symbolms -
Bit Resolution1
SAE SPN
CANBus Range-2147483648 to 2147483647
Display Range-2147483648 to 2147483647
Submit Date2011-03-09
Submit ByMatthias Meyer
Submit CompanyJohn Deere
Revision Number2
Current StatusPublished
Status Date2022-01-10
Status CommentsRenamed to SC Setpoint Turn Off Time; Comment Update
2022-01-10: Published Renamed to SC Setpoint Turn Off Time; Comment Update
2021-10-14: New Request Submitted
2011-03-16: Request Pending
2011-03-27: Request Pending
2011-03-28: ISO-Approved

Back