Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 101-200 of 330 results.
| Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0001 0000 | Aux valve 11 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0001 0000 | Aux valve 11 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 1000 | Aux valve 10 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 1000 | Aux valve 10 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0100 | Aux valve 10 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0100 | Aux valve 10 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0001 | Aux valve 9 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0001 | Aux valve 9 state is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0000 | No options for this option byte supported | ![]() |
| 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) bits 2 to 8 | Reserved for ISO assignment | ![]() |
| 5 | Aux-N inputs | (Byte 2) bit 8 | Reserved for ISO assignment | ![]() |
| 6 | Aux-N functions | (Byte 2) bit 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | ![]() |
| 11 | Task Controller Section Control (TC-SC) Server | (Byte 2) 1 to 255 | Number of supported sections | ![]() |
| 12 | Task Controller Section Control (TC-SC) Client | (Byte 2) 1 to 255 | Number of supported sections | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0100 0000 | Supports type 14 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0100 0000 | Supports type 14 function | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0100 0000 | Aux valve 8 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0100 0000 | Aux valve 8 state is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0010 0000 | Supports type 13 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0010 0000 | Supports type 13 function | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0001 0000 | Supports type 12 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0001 0000 | Supports type 12 function | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0001 0000 | Aux valve 7 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0001 0000 | Aux valve 7 state is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0000 1000 | Supports type 11 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0000 1000 | Supports type 11 function | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 1000 | Aux valve 6 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 1000 | Aux valve 6 flow is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0000 0100 | Supports type 10 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0000 0100 | Supports type 10 function | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0100 | Aux valve 6 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0100 | Aux valve 6 state is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0000 0010 | Supports type 9 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0000 0010 | Supports type 9 function | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0010 | Aux valve 5 flow is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0010 | Aux valve 5 flow is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0000 0001 | Supports type 8 function | ![]() |
| 6 | Aux-N functions | (Byte 2) 0000 0001 | Supports type 8 function | ![]() |
| 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0001 | Polygon-based prescription maps are supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0001 | Aux valve 5 state is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0001 | Aux valve 5 state is supported | ![]() |
| 5 | Aux-N inputs | (Byte 2) 0000 0000 | No options for this option byte supported | ![]() |
| 6 | Aux-N functions | (Byte 2) 0000 0000 | No options for this option byte supported | ![]() |
| 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0001 | Guidance curvature is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0001 | Guidance curvature is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 1000 0000 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 1000 0000 | Reserved for ISO assignment | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0010 | Rear hitch position is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0010 | Rear hitch position is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0001 | Rear hitch motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0001 | Rear hitch motion is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0010 | Front hitch position is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0010 | Front hitch position is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0001 | Front hitch motion is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0001 | Front hitch motion is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0000 | No options for this option byte supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0000 | No options for this option byte supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 1000 | Rear PTO speed CCW is supported | ![]() |
| 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 1000 | Rear PTO speed CCW is supported | ![]() |
| 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 0100 | Rear PTO engagement CW is supported | ![]() |
