SPN5736
SP NameDrive strategy priority 4 request
SP DescriptionThis parameter is used to request an alteration to the tractor drive strategy priority structure, which determines the balance between fuel economy/consumption and the torque reserve of the engine. This parameter indicates the lowest priority request.

Manufacturer specific modes are intended to allow a request of a mode that is not mapped and allow an implement to synchronize to that mode.

Value Meaning
0x00 Enable maximum draft power control
0x01 Enable constant PTO speed control
0x02 Enable combined wheel/PTO speed ratio control
0x03 Enable minimum engine speed control
0x04 Enable engine economy control
0x05 Enable maximum hydraulic power control
0x06 Enable maximum electric power control
0x07 – 0xEC Reserved
0xED – 0xFC Manufacturer specific modes
0xFD Reserved
0xFE Error or reserved
0xFF Not available/Don't care
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length8 bits
Scaling256 states/8 bit
Offset0
Data Range0 to 255
Operational RangeNot set
Unitsbit
Slot Identifier93
Slot NameSAEbs08
SP TypeCommand
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)255
Length minimum (value only)8
Length maximum (value only)8
SP DocumentISO 11783-7
PG Created or Modified DateNot set
PG SP Mapping Created/Mod. DateNot set

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
64718Drive Strategy commandView