SPN | 5734 |
---|---|
SP Name | Drive strategy priority 2 request |
SP Description | This parameter is used to request an alteration to the tractor drive strategy priority structure, which determines the balance between fuel economy/consumption and the torque reserve of the engine. This parameter indicates the second highest priority request. Manufacturer specific modes are intended to allow a request of a mode that is not mapped and allow an implement to synchronize to that mode. Data length: 8 bits Value Meaning 0x00 Enable maximum draft power control 0x01 Enable constant PTO speed control 0x02 Enable combined wheel/PTO speed ratio control 0x03 Enable minimum engine speed control 0x04 Enable engine economy control 0x05 Enable maximum hydraulic power control 0x06 Enable maximum electric power control 0x07 – 0xEC Reserved 0xED – 0xFC Manufacturer specific modes 0xFD Reserved 0xFE Error or reserved 0xFF Not available/Don't care |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2015 |
SP Length | 8 bits |
Scaling | 256 states/8 bit |
Offset | 0 |
Data Range | 0 to 255 |
Operational Range | Not set |
Units | bit |
Slot Identifier | 93 |
Slot Name | SAEbs08 |
SP Type | Command |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 255 |
Length minimum (value only) | 8 |
Length maximum (value only) | 8 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |