SPN | 5737 |
---|---|
SP Name | Restore operator drive strategy setting request |
SP Description | This parameter requests the drive strategy subsystem to restore the settings for drive strategy to the state before automation was ended. Value Meaning 00 No Request (sent when implement does not want setting restored) 01 Restore Operator Drive Strategy Setting 10 Error indication 11 Not available |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2015 |
SP Length | 2 bits |
Scaling | 4 states/2 bit |
Offset | 0 |
Data Range | 0 to 3 |
Operational Range | Not set |
Units | bit |
Slot Identifier | 87 |
Slot Name | SAEbs02 |
SP Type | Command |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 3 |
Length minimum (value only) | 2 |
Length maximum (value only) | 2 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |