PGN64770
PG LabelAll implements stop operations switch state
PG AcronymAISO
PG NotesThis message may be sent by any control function (CF) connected to the implement bus on forestry or agriculture implements providing to connected systems the current state of the all implement stop operations switch.

At least one of these switches shall be in each operator location of the connected system.

All implements shall start a process to stop all operations when this broadcast message is received from any CF with a value of “Stop implement operations” (SPN 5140).. Before an implement turns off all implement operations, it shall assume a failsafe condition. If an implement is operating in an automation mode, it may enter a failsafe condition before requesting the tractor ECU to exit the automation mode, e.g. PTO, Auxiliary valve, and/or tractor movement.

The working set master for the implement shall then inform the operator that the implement has stopped all operations due to the activation of the Stop All Implement Operations switch.

Implement working set masters shall include, on their home screen, an indication, e.g. icon or a function name, if it supports Stop All Implement Operations.

The Working Set shall monitor the number of transitions for each ISB server upon receiving first the message from a given ISB server. A Working Set shall consider an increase in the transitions without detecting a corresponding transition of the Stop all implement operations state as an error and react accordingly.
Pgn Notes-
EDP0
DP0
PF253
PS2
MultipacketNo
Transmission Rate1 s and on change of state
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit7.1
PG DocumentISO 11783-7
PG Created or Modified Date2014-03-31
PG SP Mapping Created/Mod. Date2014-02-20

Linked SPNs

Displaying 1-2 of 2 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
7443Stop All Implement Operations Transition Number78 bits256 states/8 bit0View
5140Stop all implement operations8.12 bits4 states/2 bit0View