SPN | 5733 |
---|---|
SP Name | Drive strategy priority 1 request |
SP Description | This parameter is used to request an alteration to the tractor drive strategy priority structure, which determines the balance between fuel economy/consumption and the torque reserve of the engine. This parameter indicates the highest priority request. Manufacturer specific modes are intended to allow a request of a mode that is not mapped and allow an implement to synchronize to that mode. Value Meaning 0x00 Enable maximum draft power control 0x01 Enable constant PTO speed control 0x02 Enable combined wheel/PTO speed ratio control 0x03 Enable minimum engine speed control 0x04 Enable engine economy control 0x05 Enable maximum hydraulic power control 0x06 Enable maximum electric power control 0x07 – 0xEC Reserved 0xED – 0xFC Manufacturer specific modes 0xFD Reserved 0xFE Error or reserved 0xFF Not available/Don't care |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2015 |
SP Length | 8 bits |
Scaling | 256 states/8 bit |
Offset | 0 |
Data Range | 0 to 255 |
Operational Range | Not set |
Units | bit |
Slot Identifier | 93 |
Slot Name | SAEbs08 |
SP Type | Command |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 255 |
Length minimum (value only) | 8 |
Length maximum (value only) | 8 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |