| SPN | 5734 |
|---|---|
| SP Name | Drive strategy priority 2 request |
| SP Description | This parameter is used to request an alteration to the tractor drive strategy priority structure, which determines the balance between fuel economy/consumption and the torque reserve of the engine. This parameter indicates the second highest priority request. Manufacturer specific modes are intended to allow a request of a mode that is not mapped and allow an implement to synchronize to that mode. Data length: 8 bits Value Meaning 0x00 Enable maximum draft power control 0x01 Enable constant PTO speed control 0x02 Enable combined wheel/PTO speed ratio control 0x03 Enable minimum engine speed control 0x04 Enable engine economy control 0x05 Enable maximum hydraulic power control 0x06 Enable maximum electric power control 0x07 – 0xEC Reserved 0xED – 0xFC Manufacturer specific modes 0xFD Reserved 0xFE Error or reserved 0xFF Not available/Don't care |
| Sp Notes | Not set |
| Has Attachment | no |
| SP Historical Remarks | - |
| SP Historical Attachment | no |
| From 2015/2019 | 2015 |
| SP Length | 8 bits |
| Scaling | 256 states/8 bit |
| Offset | 0 |
| Data Range | 0 to 255 |
| Operational Range | Not set |
| Units | bit |
| Slot Identifier | 93 |
| Slot Name | SAEbs08 |
| SP Type | Command |
| SP Reference | Not set |
| Scale Factor (value only) | 1 |
| Offset (value only) | 0 |
| Range maximum (value only) | 255 |
| Length minimum (value only) | 8 |
| Length maximum (value only) | 8 |
| SP Document | ISO 11783-7 |
| PG Created or Modified Date | Not set |
| PG SP Mapping Created/Mod. Date | Not set |