| SPN | 4311 |
| SP Name | Machine selected speed setpoint limit |
| SP Description | This parameter is used by a machine to communicate its maximum allowed speed to the tractor. |
| Sp Notes | Not set |
| Has Attachment | no |
| SP Historical Remarks | - |
| SP Historical Attachment | no |
| From 2015/2019 | 2015 |
| SP Length | 16 bits |
| Scaling | 0.001 m/s/bit, upper byte 0.256 m/s/bit |
| Offset | 0 |
| Data Range | 0 to 64 255 m/s |
| Operational Range | Not set |
| Units | m/s |
| Slot Identifier | 125 |
| Slot Name | SAEvl01 |
| SP Type | Command |
| SP Reference | Not set |
| Scale Factor (value only) | 0.001 |
| Offset (value only) | 0 |
| Range maximum (value only) | 64.255 |
| Length minimum (value only) | 16 |
| Length maximum (value only) | 16 |
| SP Document | ISO 11783-7 |
| PG Created or Modified Date | 2011-02-03 |
| PG SP Mapping Created/Mod. Date | 2007-08-15 |
Linked PGNs
Displaying 1-1 of 1 result.
13877