SPN5801
SP NameAuxiliary valve 01 exit/reason code
SP DescriptionThis parameter is used to indicate why the auxiliary valve 01 cannot accept remote commands or has most recently stopped accepting remote commands.

Value Meaning
000000 No reason/all clear
000001 Required level of operator presence/awareness not detected
000010 Implement released control of function
000011 Operator override of function
000100 Operator control not in valid position
000101 Remote command timeout
000110 Remote command out of range/invalid
000111 Function not calibrated
001000 Operator control fault
001001 Function fault
001010 to 010011 Reserved
010100 Hydraulic oil level too low
010101 Valve locked out
010110 to 110000 Reserved
110001 to 111101 Manufacturer specific
111110 Error
111111 Not available (parameter not supported)
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length6 bits
Scaling64 states/6 bit
Offset0
Data Range0 to 63
Operational RangeNot set
Unitsbit
Slot Identifier91
Slot NameSAEbs06
SP TypeMeasured
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)63
Length minimum (value only)6
Length maximum (value only)6
SP DocumentISO 11783-7
PG Created or Modified Date2011-02-03
PG SP Mapping Created/Mod. Date2011-02-03

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65041Auxiliary valve 1 estimated flowView