SPN1925
SP NameAuxiliary valve number 02 extend port estimated flow
SP DescriptionValue reported by the flow controller through the extend port of auxiliary valve 02 of a tractor, which could be based on the commanded position of the valve.

Zero percent indicates no flow, 100 % indicates maximum flow, −100 % indicates maximum flow returning to the tractor through this port. Caution should be exercised when using this parameter in feedback control systems because this parameter is estimated and not measured.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length8 bits
Scaling1 %/bit
Offset-125
Data Range-125 to 125 %
Operational RangeNot set
Units%
Slot Identifier45
Slot NameSAEpc05
SP TypeEstimated
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)-125
Range maximum (value only)125
Length minimum (value only)8
Length maximum (value only)8
SP DocumentISO 11783-7
PG Created or Modified Date2011-02-03
PG SP Mapping Created/Mod. Date2000-08-10

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65042Auxiliary valve 2 estimated flowView