SPN9734
SP NameAuxiliary valve 02 estimated flow (high resolution)
SP DescriptionValue reported by the controller of flow out of an auxiliary valve 02 of a tractor which could be based on the commanded position of the valve.

If this parameter is “not available” (all 1’s) then only the original resolution parameters (see SPN 2337 and 2338) are populated.

0 % indicates no flow, 100 % indicates maximum flow out the extend port, −100 % indicates maximum flow out the retract port. Caution should be exercised when using this parameter in feedback control systems because this parameter is estimated and not measured.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192018
SP Length16 bits
Scaling0.004 %/bit
Offset-125
Data Range-125 to 132.02 %
Operational Range-100 to 100 %
Units%
Slot Identifier264
Slot NameSAEpc09
SP TypeEstimated
SP ReferenceNot set
Scale Factor (value only)0.004
Offset (value only)-125
Range maximum (value only)132.02
Length minimum (value only)16
Length maximum (value only)16
SP DocumentISO 11783-7
PG Created or Modified Date2011-02-03
PG SP Mapping Created/Mod. Date2017-11-20

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65042Auxiliary valve 2 estimated flowView