SPN | 2410 |
---|---|
SP Name | Language Code |
SP Description | Command sent to all ECUs specifying the operator's desired language of information. ISO 11783 networks shall use the two-letter language codes in accordance with ISO 639. EXAMPLE Dutch: nl; French: fr; English: en; German: de. |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2018 |
SP Length | 16 bits |
Scaling | 7 bit ISO Latin 1 characters (lower case) |
Offset | 0 |
Data Range | 97 to 122 per byte |
Operational Range | Not set |
Units | 7 bit ISO Latin 1 characters (lower case) |
Slot Identifier | 131 |
Slot Name | SAEatf0002 |
SP Type | Command |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 255 |
Length minimum (value only) | 16 |
Length maximum (value only) | 16 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | 2000-08-10 |
PG SP Mapping Created/Mod. Date | 2000-08-10 |