PGN | 65033 |
---|---|
PG Label | Tractor Facilities response message |
PG Acronym | TFR |
PG Notes | Tractor response to an implement CF or a task controller request for tractor classification and facilities. |
Pgn Notes | As of the third edition of this document, "Lighting - minimal set as existing trailer connector" is no longer a requirement of Classification 1. It is part of the Classification 2 requirements. If Byte 8/Bit 1 is set to “1”, the following bits need to be considered “Reserved”: Byte 2, Bits 1, 2 Byte 4, Bits 1 to 4 Byte 5, Bits 1 to 5 Byte 7, Bits 1 to 8 Byte 8, Bits 2 to 8 Reserved bits must be set to “0” to allow “1” to indicate that newer facilities are supported. Since previous versions of the standard did not mention this, they were set to “1” as is customary for reserved bits. |
EDP | 0 |
DP | 0 |
PF | 254 |
PS | 9 |
Multipacket | No |
Transmission Rate | On power-up and then on request |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 3.8 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |
Linked SPNs
Displaying 1-46 of 46 results.
SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
---|---|---|---|---|---|---|
5235 | Speed information - engine speed | 1.1 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed information - ground-based speed | 1.2 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed information - wheel-based speed | 1.3 | 1 bit | 2 states/1 bit | 0 | |
5235 | Power management - maintain power | 1.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | Power management - maximum time tractor power | 1.5 | 1 bit | 2 states/1 bit | 0 | |
5235 | Power management - key switch | 1.6 | 1 bit | 2 states/1 bit | 0 | |
5234 | Tractor ECU class response | 1.7 | 2 bits | 4 states/2 bit | 0 | |
5235 | Language command storage in Tractor ECU | 2.3 | 1 bit | 2 states/1 bit | 0 | |
5235 | Lighting - minimal set as existing trailer connector | 2.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO information - rear shaft engagement | 2.5 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO information - rear shaft speed | 2.6 | 1 bit | 2 states/1 bit | 0 | |
5235 | Hitch information - rear in work | 2.7 | 1 bit | 2 states/1 bit | 0 | |
5235 | Hitch information - rear position | 2.8 | 1 bit | 2 states/1 bit | 0 | |
5235 | Estimated or measured auxiliary valve status | 3.1 | 1 bit | 2 states/1 bit | 0 | |
5235 | Lighting - full implement lighting message set | 3.2 | 1 bit | 2 states/1 bit | 0 | |
5235 | Additional hitch parameters - rear draft | 3.3 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed and distance - wheel-based direction | 3.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed and distance - wheel-based distance | 3.5 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed and distance - ground-based direction | 3.6 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed and distance - ground-based distance | 3.7 | 1 bit | 2 states/1 bit | 0 | |
5235 | Time date | 3.8 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO commands - rear PTO mode/gear command | 4.3 | 1 bit | 2 states/1 bit | 0 | |
7444 | Tractor facility response - Limit/request status reporting | 4.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | Auxiliary valve commands | 4.5 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO commands - rear PTO engagement command | 4.6 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO commands - rear PTO speed command | 4.7 | 1 bit | 2 states/1 bit | 0 | |
5235 | Hitch commands - rear hitch position | 4.8 | 1 bit | 2 states/1 bit | 0 | |
5235 | Direction control | 5.1 | 1 bit | 2 states/1 bit | 0 | |
5235 | Machine selected speed control | 5.2 | 1 bit | 2 states/1 bit | 0 | |
5235 | Machine selected speed | 5.3 | 1 bit | 2 states/1 bit | 0 | |
5235 | Operator external light controls | 5.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | Navigational pseudo-range noise statistics | 5.6 | 1 bit | 2 states/1 bit | 0 | |
5235 | Navigational system position data | 5.7 | 1 bit | 2 states/1 bit | 0 | |
5235 | Navigational system high-output position | 5.8 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO commands - front PTO engagement command | 6.1 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO commands - front PTO speed command | 6.2 | 1 bit | 2 states/1 bit | 0 | |
5235 | Hitch commands - front hitch position | 6.3 | 1 bit | 2 states/1 bit | 0 | |
5235 | Additional hitch parameters - front draft | 6.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO information - front shaft engagement | 6.5 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO information - front shaft speed | 6.6 | 1 bit | 2 states/1 bit | 0 | |
5235 | Hitch information - front in work | 6.7 | 1 bit | 2 states/1 bit | 0 | |
5235 | Hitch information - front position | 6.8 | 1 bit | 2 states/1 bit | 0 | |
5235 | Drive Strategy Status and Commands | 7.1 | 1 bit | 2 states/1 bit | 0 | |
5235 | External Guidance Status and Commands | 7.2 | 1 bit | 2 states/1 bit | 0 | |
5235 | PTO commands - front PTO mode/gear command | 7.8 | 1 bit | 2 states/1 bit | 0 | |
5236 | Tractor facility reserved bit indicator | 8.1 | 1 bit | 2 states/1 bit | 0 |