PGN65080
PG LabelAuxiliary valve 8 command
PG AcronymAV08C
PG NotesMessage that provides control of the flow through the auxiliary valve number 8.
Pgn Notes-
EDP0
DP0
PF254
PS56
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit3.1
PG DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
2259Auxiliary valve number 8 port flow — Command18 bits0.4 %/bit0View
7880Auxiliary valve number 8 Resolution mode — Command2.12 bits4 states/2 bit0View
2260Auxiliary valve number 8 state — Command3.14 bits16 states/4 bit0View
2261Auxiliary valve number 8 fail safe mode — Command3.72 bits4 states/2 bit0View
7864Auxiliary valve number 8 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View