PGN65087
PG LabelAuxiliary valve 15 command
PG AcronymAV15C
PG NotesMessage that provides control of the flow through the auxiliary valve number 15.
Pgn Notes-
EDP0
DP0
PF254
PS63
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit2.1
PG DocumentISO 11783-7
PG Created or Modified Date2015-05-07
PG SP Mapping Created/Mod. Date2015-05-07

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
2343Auxiliary valve number 15 port flow — Command18 bits0.4 %/bit0View
7887Auxiliary valve number 15 Resolution mode — Command2.12 bits4 states/2 bit0View
2344Auxiliary valve number 15 state — Command3.14 bits16 states/4 bit0View
2345Auxiliary valve number 15 fail safe mode — Command3.72 bits4 states/2 bit0View
7871Auxiliary valve number 15 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View