PGN65072
PG LabelAuxiliary valve 0 command
PG AcronymAV00C
PG NotesMessage that provides control of the flow through the auxiliary valve number 0.
Pgn NotesThis valve is used for “power beyond” control.
EDP0
DP0
PF254
PS48
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit3.1
PG DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
1907Auxiliary valve number 0 port flow — Command18 bits0.4 %/bit0View
7872Auxiliary valve number 0 Resolution mode — Command2.12 bits4 states/2 bit0View
1908Auxiliary valve number 0 state — Command3.14 bits16 states/4 bit0View
1909Auxiliary valve number 0 fail safe mode — Command3.72 bits4 states/2 bit0View
7856Auxiliary valve number 0 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View