PGN65074
PG LabelAuxiliary valve 2 command
PG AcronymAV02C
PG NotesMessage that provides control of the flow through the auxiliary valve number 2.
Pgn Notes-
EDP0
DP0
PF254
PS50
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit4.1
PG DocumentISO 11783-7
PG Created or Modified Date2015-05-07
PG SP Mapping Created/Mod. Date2015-05-07

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
1931Auxiliary valve number 2 port flow — Command18 bits0.4 %/bit0View
7874Auxiliary valve number 2 Resolution mode — Command2.12 bits4 states/2 bit0View
1932Auxiliary valve number 2 state — Command3.14 bits16 states/4 bit0View
1933Auxiliary valve number 2 fail safe mode — Command3.72 bits4 states/2 bit0View
7858Auxiliary valve number 2 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View