PGN65094
PG LabelSecondary or Front Hitch Status
PG AcronymFHS
PG NotesMessage providing the measurement of the current front hitch parameters.

Value Meaning
000000 No reason/all clear
000001 Required level of operator presence/awareness not detected
000010 Implement released control of function
000011 Operator override of function
000100 Operator control not in valid position
000101 Remote command timeout
000110 Remote command out of range/invalid
000111 Function not calibrated
001000 Operator control fault
001001 Function fault
001010 to 010011 Reserved
010100 Hydraulic oil level too low
010101 Hitch locked out
010110 to 110000 Reserved
110001 to 111101 Manufacturer specific
111110 Error
111111 Not available (parameter not supported)
Pgn Notes-
EDP0
DP0
PF254
PS70
MultipacketNo
Transmission Rate100 ms
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit6.1
PG DocumentISO 11783-7
PG Created or Modified Date2011-02-03
PG SP Mapping Created/Mod. Date2011-02-03

Linked SPNs

Displaying 1-6 of 6 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
1872Front Hitch Position18 bits0.4 %/bit0View
5150Front Hitch Position Limit status2.43 bits8 states/3 bit0View
1876Front Hitch In-work Indication2.72 bits4 states/2 bit0View
1880Front Nominal Lower Link Force38 bits0.8 %/bit-100View
1878Front Draft4-516 bits10 N/bit-320000View
5816Front hitch exit/reason code6.16 bits64 states/6 bit0View