SPN5203
SP NameImplement Start/Stop operations
SP DescriptionState of a switch or other operator input to start or enable implement operations. The start or enabled state can be the result of the implement being positioned in an operating position. It can be generated by an operator placing a switch to an ON state. Also called “Master ON/OFF” switch.

Value Meaning
00 Stop or disable implement operations
01 Start or enable implement operations
10 Error indication
11 Not available
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length2 bits
Scaling4 states/2 bit
Offset0
Data Range0 to 3
Operational RangeNot set
Unitsbit
Slot Identifier87
Slot NameSAEbs02
SP TypeMeasured
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)3
Length minimum (value only)2
Length maximum (value only)2
SP DocumentISO 11783-7
PG Created or Modified DateNot set
PG SP Mapping Created/Mod. DateNot set

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65096Wheel-based Speed and DistanceView