PGN | 65094 |
---|---|
PG Label | Secondary or Front Hitch Status |
PG Acronym | FHS |
PG Notes | Message providing the measurement of the current front hitch parameters. Value Meaning 000000 No reason/all clear 000001 Required level of operator presence/awareness not detected 000010 Implement released control of function 000011 Operator override of function 000100 Operator control not in valid position 000101 Remote command timeout 000110 Remote command out of range/invalid 000111 Function not calibrated 001000 Operator control fault 001001 Function fault 001010 to 010011 Reserved 010100 Hydraulic oil level too low 010101 Hitch locked out 010110 to 110000 Reserved 110001 to 111101 Manufacturer specific 111110 Error 111111 Not available (parameter not supported) |
Pgn Notes | - |
EDP | 0 |
DP | 0 |
PF | 254 |
PS | 70 |
Multipacket | No |
Transmission Rate | 100 ms |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 6.1 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | 2011-02-03 |
PG SP Mapping Created/Mod. Date | 2011-02-03 |
Linked SPNs
Displaying 1-6 of 6 results.
SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
---|---|---|---|---|---|---|
1872 | Front Hitch Position | 1 | 8 bits | 0.4 %/bit | 0 | |
5150 | Front Hitch Position Limit status | 2.4 | 3 bits | 8 states/3 bit | 0 | |
1876 | Front Hitch In-work Indication | 2.7 | 2 bits | 4 states/2 bit | 0 | |
1880 | Front Nominal Lower Link Force | 3 | 8 bits | 0.8 %/bit | -100 | |
1878 | Front Draft | 4-5 | 16 bits | 10 N/bit | -320000 | |
5816 | Front hitch exit/reason code | 6.1 | 6 bits | 64 states/6 bit | 0 |