PGN65081
PG LabelAuxiliary valve 9 command
PG AcronymAV09C
PG NotesMessage that provides control of the flow through the auxiliary valve number 9.
Pgn Notes-
EDP0
DP0
PF254
PS57
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit4.1
PG DocumentISO 11783-7
PG Created or Modified Date2015-05-07
PG SP Mapping Created/Mod. Date2015-05-07

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
2271Auxiliary valve number 9 port flow — Command18 bits0.4 %/bit0View
7881Auxiliary valve number 9 Resolution mode — Command2.12 bits4 states/2 bit0View
2272Auxiliary valve number 9 state — Command3.14 bits16 states/4 bit0View
2273Auxiliary valve number 9 fail safe mode — Command3.72 bits4 states/2 bit0View
7865Auxiliary valve number 9 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View