PGN65082
PG LabelAuxiliary valve 10 command
PG AcronymAV10C
PG NotesMessage that provides control of the flow through the auxiliary valve number 10.
Pgn Notes-
EDP0
DP0
PF254
PS58
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit3.1
PG DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
2283Auxiliary valve number 10 port flow — Command18 bits0.4 %/bit0View
7882Auxiliary valve number 10 Resolution mode — Command2.12 bits4 states/2 bit0View
2284Auxiliary valve number 10 state — Command3.14 bits16 states/4 bit0View
2285Auxiliary valve number 10 fail safe mode — Command3.72 bits4 states/2 bit0View
7866Auxiliary valve number 10 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View