PGN | 65086 |
---|---|
PG Label | Auxiliary valve 14 command |
PG Acronym | AV14C |
PG Notes | Message that provides control of the flow through the auxiliary valve number 14. |
Pgn Notes | - |
EDP | 0 |
DP | 0 |
PF | 254 |
PS | 62 |
Multipacket | No |
Transmission Rate | 100 ms when active |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 4.1 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | 2015-05-07 |
PG SP Mapping Created/Mod. Date | 2015-05-07 |
Linked SPNs
Displaying 1-5 of 5 results.
SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
---|---|---|---|---|---|---|
2331 | Auxiliary valve number 14 port flow — Command | 1 | 8 bits | 0.4 %/bit | 0 | |
7886 | Auxiliary valve number 14 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
2332 | Auxiliary valve number 14 state — Command | 3.1 | 4 bits | 16 states/4 bit | 0 | |
2333 | Auxiliary valve number 14 fail safe mode — Command | 3.7 | 2 bits | 4 states/2 bit | 0 | |
7870 | Auxiliary valve number 14 port flow — Extended Resolution Command | 4-5 | 16 bits | 0.0015625 %/bit | 0 |