SPN2375
SP NameCentre stop lights — Command
SP DescriptionCommand for activating or deactivating the tractor's and implement's centre stop lights.

Value Meaning
00 Deactivate
01 Activate
10 Reserved
11 Don't care
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length2 bits
Scaling4 states/2 bit
Offset0
Data Range0 to 3
Operational RangeNot set
Unitsbit
Slot Identifier87
Slot NameSAEbs02
SP TypeCommand
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)3
Length minimum (value only)2
Length maximum (value only)2
SP DocumentISO 11783-7
PG Created or Modified Date2010-05-20
PG SP Mapping Created/Mod. Date2000-08-10

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65089Lighting commandView